RT/ZHLS, A-2Y(L)2Y External Telephone Cables to NR/PS/TEL/00015
Application
The cables are designed primarily for trackside railway installation in non electrifi ed area. For direct burial application, brass tape armoured or Zetabon type corrugated steel tape armoured can be offered against rodent attack.
Standard
- NR/PS/TEL/00015 (formerly RT/E/PS/00015 or GK/RT 0315)
- TS0886/BR1822
- BR892
Cable Construction
- Conductors: Solid plain copper conductor, 0.63 or 0.9 mm nominal diameter.
- Insulation: Solid polyethylene to BS 6234.
- Cabling Element: Two insulated conductors are twisted together to form a pair.
- Stranding: Pairs are helically stranded in 10 pair units.
- Core Wrapping: Plastic tape(s) with overlapping.
- Moisture Barrier: One laminated sheath made of aluminium tape (0.15mm) coated with PE-Copolymer on at least one side is applied with longitudinally overlap.
- Outer Sheath: Polyethylene to BS 6234. LSZH compound option can be offered upon request.
Optional
- Jelly Filled Cables: The cable core interstices are fi lled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core.
- Armoured Cables: Corrugated steel tape armour coated on both sides with copolymer can be applied over an intermediate sheath. The steel tape thickness is 0.145mm. Brass tape armour can be offered as an option.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 0.63 | 0.9 |
Maximum Conductor Resistance | Ω/km | 60.0 | 30.0 |
Minimum Insulation Resistance @500 V DC (1min) | MΩ.km | 1500 | 1500 |
Maximum Conductor Capacitance @1000Hz (AC) | |||
Maximum Average Value | |||
For 20 pairs or less | nF/km | 70 | 79 |
More than 20 pairs | nF/km | 67 | 75 |
Maximum Individual Value 99% of pairs | |||
Up to 20 pairs | nF/km | 79.0 | 85.0 |
More than 20 pairs | nF/km | 75.0 | 81.0 |
Maximum Capacitance Unbalance @1000Hz pair to pair (99% of pairs) | |||
For 2 pairs (1 quad) | pF/500m | 800 | 800 |
All other sizes | pF/500m | 275 | 275 |
Dielectric Strength, conductor to screen (DC voltage 2mins) | V | 2000 | 2000 |
Maximum Average Attenuation | |||
@1.0KHz | dB/km | 1.40 | 0.95 |
@2.4KHz | dB/km | 2.15 | 1.46 |
@1.024MHz | dB/km | 18.70 | 14.6 |
Minimum Average Near-end Crosstalk | |||
@1.0KHz | dB/km | 70 | 70 |
@2.4KHz | dB/km | 65 | 65 |
@1.024MHz | |||
Within Units | dB/km | 40 | 40 |
Between Units | dB/km | 47 | 47 |
High Voltage Breakdown Test | |||
DC for 2mins | V | 2000 | 2000 |
AC for 2mins | V | 1333 | 1333 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 7.5×OD (unarmoured); 10×OD (armoured)
- Temperature Range: -40℃ to +70℃ (during operation); -10℃ +60℃ (during installation)
Core Identification
Dimensions and Weight
A-2Y(L)2Y n×2×0.63/0.9
Cable Code | Number of Pairs (n) |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|
0.63mm Conductor, 1.15mm Insulated Wire | ||||
RS/RT/ZHLS-2Y(L)2Y-2P0.63 | 2 | 2.7 | 12.3 | 103 |
RS/RT/ZHLS-2Y(L)2Y-5P0.63 | 5 | 2.7 | 13.8 | 155 |
RS/RT/ZHLS-2Y(L)2Y-10P0.63 | 10 | 2.7 | 15.6 | 212 |
RS/RT/ZHLS-2Y(L)2Y-20P0.63 | 20 | 2.7 | 18.1 | 309 |
RS/RT/ZHLS-2Y(L)2Y-30P0.63 | 30 | 2.7 | 20.4 | 403 |
RS/RT/ZHLS-2Y(L)2Y-50P0.63 | 50 | 2.7 | 24.2 | 574 |
RS/RT/ZHLS-2Y(L)2Y-75P0.63 | 75 | 2.7 | 28.2 | 779 |
RS/RT/ZHLS-2Y(L)2Y-100P0.63 | 100 | 2.7 | 31.0 | 974 |
0.9mm Conductor, 1.5mm Insulated Wire | ||||
RS/RT/ZHLS-2Y(L)2Y-2P0.9 | 2 | 2.7 | 13.3 | 131 |
RS/RT/ZHLS-2Y(L)2Y-5P0.9 | 5 | 2.7 | 15.6 | 208 |
RS/RT/ZHLS-2Y(L)2Y-10P0.9 | 10 | 2.7 | 18.1 | 305 |
RS/RT/ZHLS-2Y(L)2Y-20P0.9 | 20 | 2.7 | 21.9 | 477 |
RS/RT/ZHLS-2Y(L)2Y-30P0.9 | 30 | 2.7 | 25.2 | 639 |
RS/RT/ZHLS-2Y(L)2Y-50P0.9 | 50 | 2.7 | 30.0 | 951 |
RS/RT/ZHLS-2Y(L)2Y-75P0.9 | 75 | 2.7 | 35.8 | 1325 |
RS/RT/ZHLS-2Y(L)2Y-100P0.9 | 100 | 2.7 | 39.1 | 1688 |
A-2Y(F)(L)2YB2Y n×2×0.63/0.9 Jelly Filled & Armoured Cables
Cable Code | Number of Pairs (n) |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
|
---|---|---|---|---|---|
Inner | Outer | ||||
0.63mm Conductor, 1.15mm Insulated Wire | |||||
RS/RT/ZHLS-2Y(F)(L)2YB2Y-2P0.63 | 2 | 1.6 | 1.6 | 18.0 | 222 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-5P0.63 | 5 | 1.6 | 1.6 | 19.5 | 296 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-10P0.63 | 10 | 1.6 | 1.6 | 20.3 | 383 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-20P0.63 | 20 | 1.6 | 1.6 | 23.8 | 504 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-30P0.63 | 30 | 1.6 | 1.6 | 26.1 | 606 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-50P0.63 | 50 | 1.6 | 1.6 | 29.9 | 903 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-75P0.63 | 75 | 1.6 | 1.6 | 33.9 | 1202 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-100P0.63 | 100 | 1.6 | 1.6 | 36.7 | 1463 |
0.9mm Conductor, 1.5mm Insulated Wire | |||||
RS/RT/ZHLS-2Y(F)(L)2YB2Y-2P0.9 | 2 | 1.6 | 1.6 | 19.0 | 250 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-5P0.9 | 5 | 1.6 | 1.6 | 21.3 | 370 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-10P0.9 | 10 | 1.6 | 1.6 | 23.8 | 508 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-20P0.9 | 20 | 1.6 | 1.6 | 27.6 | 782 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-30P0.9 | 30 | 1.6 | 1.6 | 30.9 | 1000 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-50P0.9 | 50 | 1.6 | 1.6 | 35.7 | 1402 |
RS/RT/ZHLS-2Y(F)(L)2YB2Y-75P0.9 | 75 | 1.6 | 1.6 | 41.5 | 2055 |